+ 48 602 120 990 biuro@modus.org.pl

It may not display this or other websites correctly. Click on an EnergyBar outlet you would like to have turn OFF when a leak probe detects water. 12.28 . My Apex tutorial series is being picked up by Reef2Reef! I use the OSC command to activate my Swabbie skimmer neck cleaner every six hours. Since the Maintenance virtual output doesnt actually run any program (other than its default Set OFF command), the only way to activate Maintenance mode is to manually move the slider to the ON position: When you complete your maintenance, move the slider to the OFF position: Since this output doesnt have any programming, I prefer to always leave it in the manual OFF position rather than AUTO, even though in this particular example it doesnt make a difference. It is a great reminder that I need to dig deeper into my Apex. After testing, remember to add that line back to the programming since its there as a safeguard. Lowered the When command timer from 5 minutes down to 3 minutes. The Apex gives you a number of choices on how to program outputs based on timers, each with a specific purpose: OSC: A repeating On/Off interval, where you specify the number of minutes & seconds to be ON, and the number of minutes and seconds to be OFF If Time: Turn on or off between specific times on the clock, down to the minute Recalling from our Timers tutorial, the Defer timer is used to prevent false alarms due to ripples on the liquid surface inadvertently triggering the optical sensor (in my case, if I accidentally bump the container when its nearly low, but not quite at the sensor yet). Click the Advanced (gear icon) at the top of the Fusion dashboard to expand the list of icons, Click the Add/Delete (gear icon) at the upper right, then click Add a virtual output. Defer 000:10 Then ON Once that timer expires, the specified programming commands will operate again as normal. Switch the Control Type to Advanced. Enter a descriptive name for the new output. For testing purposes, you can lower the Defer timers, or delete them. Item specifics Condition: Used: An item that has been previously used. You cannot specify the same value for the start and end times, so 10:00 to 10:00 is invalid. Reef2Reef is extremely grateful to For Inspiration: A beautiful 15-liter reef tank. Added an additional optical sensor named FW_LOW inside my 75-gallon RO/DI storage tank to turn off the ATK if the water level is too low. If Time 07:00 to 21:00 Then OFF, Set OFF Click the Update Settings button to save the new name to the Apex. $29.99 . The Magnetic Optical Sensor replaces our optical sensor with magnet and offers an improved look, feel, and magnetic design that also lends itself to help prevent water incursion into the sensor. The best way to avoid excess notifications is to use a virtual output with its own programming including a timer, and then use that virtual outputs state in your alarm programming. The item may have some signs of cosmetic wear, but is . If ATK_HI CLOSED Then OFF This tutorial will explain each line of code, how to troubleshoot the ATK, and how to modify and enhance the programming for additional features. Once that condition is no longer True, and if no other command turns the outlet On, then the output is turned Off and the alarm is cleared. NjgzNjhjYTgxNDUzZTQ0MDkxMTJlZGMxMjkzOTU0MzVlMTRhNDk5MDg3MTEw ZGExZjNjMDRiZjNlOGMwZWEwYjYyN2Q1NGRhZjQ1YzAyMTMxOWQwMWYzNTA5 In this example, the If Time command is true from 12:00 to 12:59, but the DOW command will evaluate True only on Saturday since thats the only placeholder not replaced with a hyphen. Added an additional optical sensor named FW_LOW inside my 75-gallon RO/DI storage tank to turn off the ATK if the water level is too low. NDgyYjJiY2JiYjI5ODZlZjJjZmRiNTIxYTdmZjFjMDNjZmY3MGRmNTQ4MjU0 IMPORTANT LEAK DETECTION PROBE PLACEMENT NOTES. If it doesn't move any water, verify the 24v power adapter is firmly plugged in to the FMM and that it has power. Neptune FMM for ATO | Marine and Reef General Discussion | MARSH New posts Search forums Welcome back Guest! If you noticed in my Radion screenshot above, I have additional profiles listed in the Advanced coding. Turns off powerheads, skimmer, and sets return pump to 1% for 5 minutes, and activates feeder for one rotation. MjIxNDg4NGFjM2RhOGIxNjgyYTI5OGY0NzZhODU3ZDczN2ViODQ1NWNiOTll The odd thing about the initial delay timer is that it calculates from midnight of January 1, 1996. In those situations, a virtual output can be used to trigger the alarm, but then turn itself off so the alarm doesnt repeat every hour. I add an optical sensor to my existing apex based ato to act as my primary sensor. ODdkY2NlOTEzMTUxMzZmM2FkN2RmOTYxMmY1NzFhM2JkODRiYWMzZWY4NGY1 | Neptune Apex Setup Guide BRStv - Saltwater Aquariums & Reef Tanks 24K views 2 years ago Vlog 40: Two Vats, One Pump - the. (sorry to those non-basketball fans reading this). This means that the shortest duration you can run an output using If Time is actually two minutes. YWQ4NmZkYzMzMjFhMjk5Y2YyMTQ1ZjZmZmY3ZTE3MWY0ZWMwNDNmNGQwOGU5 If LkSump CLOSED Then OFF Hopefully this will get you started with creating some convenient automation for your setup. APEX PRO Solid Surface Leak Sensor When it comes to water on the floor, time is critical. Neptune Systems Apex Tutorials - Cameras Reef Automation 4.1K views 1 year ago 3 EASY WAYS TO HIDE WIRES CABLES IN WALL & FIND STUDS TampaTec 4.1M views 4 years ago Reef Automation Live Stream. . The fifth tile is for the 24V ACC port, which will have a name in the format of LinkA_#_1, where # is the Apex AquaBus address of the FMM. When you first connect your FMM you will have five new tiles on your Apex Fusion Dashboard. The Defer statements are then controlling how long to wait before setting the output state. However, with my 30+ year career in IT systems and my love of all things automation, I realized I could leverage my technical background and the Apex to automate most functions on the aquarium. Entdecke 3D-gedruckter Neptun COR15 COR20 Pumpeneinlassschutz in groer Auswahl Vergleichen Angebote und Preise Online kaufen bei eBay Kostenlose Lieferung fr viele Artikel! For my swabbie, I just copied your homework and never looked back! It seems to cycle over a 30-40 minute period. Thanks! Defer 005:00 Then ON, If Moon [+/-] [DELAY] / [+/-] [DELAY] Then [ON/OFF/PROFILE], If Moon 000/000 Then ON - Turn on at moonrise, and off at moonset Next, lets look at some examples that involve a bit more programming. Enable logging on the PMUP output. While the LD-2 utilizes conductive strips to detect fluid leaks on surfaces around your aquarium, the LD-3 takes advantage of optical sensor technology instead. You can test a leak detection probe by placing the probe on a wet paper towel. Official Neptune Systems Apex Community Group: Tmp200 = temperature probe in your 200 gallon tank, TmpFrg = temperature probe in your frag tank, TmpMix = temperature probe in your mixing station, 000:00 = zero minutes from midnight until the first run, 358:00 = 5 hours & 58 minutes to delay until the next run, Defer - will delay an outlet from changing its state for a specified period of time, Min Time - will ensure an outlet stays in its current state for a minimum period of time. So well written and explained and so happens I am transferring ATK to my new tank, and will use this as a reminder of the install. Ill cover virtual outputs in another tutorial. The remainder of this Get Started guide is for those who want to learn more, who want do the LDK configuration manually, or who desire any Apex outputs other than the email alarm to be controlled if there is a leak or water on the floor detected. You are using an out of date browser. $16.99 . (wow, I just got an alarm about my 2-part container being lowperfect timing to describe an example of a non-critical alarm that doesnt need to nag me every hour). This concludes my Apex programming series. If Tmp > 78.0 Then OFF Equipment Discussion for Saltwater and Reef Aquari, This photo is from the Reef2Reef archives courtesy of, Neptune Apex Programming Tutorials, Part 3: Automatic Top-Off Kit (ATK), https://www.neptunesystems.com/getstarted/atk-help/, Wisconsin - Florida delayed due 2 hurricane damage, https://www.reef2reef.com/ams/neptune-apex-programming-tutorials-part-4-power-monitoring.698/, Neptune ATK V2 Auto Top Off with Leak Detect probe, Using ATK with PMUP during day, and DOS over night for KALK. In this Get Started Guide well show how to configure the FMM as a leak detection module. The Neptune Optical Sensor plugs directly into the FMM allowing you to monitor the level of your sump, mixing station, or any other reservoir with liquid in it. In other words, if there are 3 different lines of code that all evaluate True and turn the output On, only the last one will be displayed in your notification email or text message. Your article clarified the whole thing. Set OFF NGMzMDViZWM2YWI0YjljMmUzOTY3NTY5NDM0M2FjNzhjZWI5ZDJjNTFlZmZm While the LD-2 utilizes conductive strips to detect fluid leaks on surfaces around your aquarium, the LD-3 takes advantage of optical sensor technology instead. Cant believe these articles dont have more likes. OUR ORIGINAL AQUARIUM CONTROLLER The Apex Classic is the original Apex introduced in 2009. Announcing the BRAND NEW Orphek Atlantik iCon! Protect your aquarium and your home Optical sensors are the go to sensor if you want a reliable sensor over a long period. Go into the FMM module settings, click Configure, then confirm outlets 1 and 2 are both detected as Optical Sensors: 101 sold . Rated at 12V, 700 mA, 2.1 mm tip. If Output Alert_FW_HI = ON Then ON Fill in the intensities for each color spectrum. In this example, the output register is set to ON if the moon is visible, but its turned OFF if the time is between 7am - 9pm. These alarm outputs named SndAlm_I6 and SndWrn_I7 serve no purpose if you dont have the display module, even though they are still listed as outputs on every Apex unit, including current models. You will need to purchase a Neptune FMM Module (Fluid Monitoring Module) to use it. All of you here at PNWMAS get to binge read all the topics this week, while the R2R audience will just have to wait. Here is a reference guide for all of the Neptune Apex programming commands. FeedB Feeding corals. It operates by water level building in the tray and then triggering an optical sensor in the tray to tell the motor to advance the fleece. In my sump, the ATK should never need to run for more than about 1-2 minutes, so three would be abnormal. I send them to both email and my iPhone for redundancy. ZmI0ZTE5NmZlYjM2M2MxYTMzYjJmYzY3YjVkZTdlNzVlNTI0MGMyYTFlZjk5 All 4 tiles will appear even if a probe or other type of sensor is not plugged into every port. For complete details including how to initially set up the Apex, modules, and configuring Fusion, see Neptunes official documentation: https://www.neptunesystems.com/support/docs/. Ive used them many times, and I know Ill be using them many more. Instead, use a low-profile leak probe, lift the edge of the carpet and padding a bit and slip the probe underneath. I can see the wattage vary in what looks like steps. It is sold as a bundled package of components that can be plugged in and quickly programmed through a task wizard in Fusion. Virtual outputs are really useful! Before getting into the programming steps, there are some prerequisites needed for power monitoring to work: Once these steps are done, you can configure various outlets on your Energy Barto react when your house power goes out. I guess we would use the half cycle time as average even though its probably not linear. These sensors are sold individually. YjM3MmQ5OWUxNzYzZDRhNDcxZDA2M2IwYzJkMTNkNjcyNmFjZTgzMjFlNzI4 Looking forward to more in this series. The simplest method for probes or certain Inputs is to use the built-in alarm feature on its configuration page. The sensors can be mounted into custom brackets or through a hole in a vessel. Select the method of notification. Hello and welcome to my new quest, Alchemical Blade Prequel Quest! I hope this was useful and helps you better understand the powerful system you have at your disposal to control your aquarium gear. Heres how to program a one-time alert using a virtual output named Alert_2Part: This single virtual output is checking both my alkalinity container and calcium container. This sensor can be used for constructing your own ATO (auto-top-off), as a high-level warning sensor in your sump, water storage level sensor, and much more. We just thought Cairns, Australia was really popular at that time of year. The best way to incorporate an automated feeder and mimic the Feed Cycle buttons is to use a virtual output to control everything. This section is for those who prefer to set things up manually, or who simply want to learn more. However, if you decide to rename a component later, any existing programming will be automatically updated to reflect the new name. In this video I explain how to set up and use the OS-1 Optical Level Sensor V2 by Neptune Systems in your Apex Fusion dashboard. If Output Alert_Power = ON Then ON Sign Up Now Leverage your professional network, and get hired. Just like the manual Feed Cycle buttons, but all unattended! 16.38 . If Power Apex Off 000 Then OFF, Fallback OFF Ensure your optical sensor plugs are firmly seated in the FMM sockets. This sensor plugs into your FMM and, using reflected infrared light, will signal your Apex when it changes state from being wet to dry or dry to wet. Earn 8,985 Reward Points, Earn 39 Reward Points In my Email_Alarm output, I added this line: This triggers the actual email and text message. The Apex can also send an alert when the power is out as long as your Internet router is on battery power as well. These sensors are sold individually. Pasted as rich text. For trivial things, such as the skimmer cup full example above, this can be very annoying. These outputs are physical, tangible electrical outlets that have power cords plugged in. If water ever touches the sensor, your ApexController will be instantly $599.95Regular Price:$ Add to CartNotify Me When In-Stock . Min Time 030:00 Then OFF, If Output output_name [Amps/Watts] [] Then [ON/OFF], Fallback OFF This is available for: You can either us the Basic alarm settings, where it will trigger an alarm if above or below your specified values: or use Advanced alarm settings which gives you more flexibility: Any Inputs with alarms configured will display a checkmark under the Alarm column in the list of Inputs: For items that dont have built in alarm settings on the configuration page, you must add lines of program code to the EmailAlm output. This should cause the pump to turn off: If both the lower sensor and the upper sensor both fail, the float valve will pinch the tubing to stop the water flow: While this should prevent a flood in your house, it will not turn off the pump since this is a simple mechanical valve and does not communicate with the Apex. Just think through your priorities when sequencing your alarm programming. If you have any questions, or have a request for an additional tutorial topic, let me know. Neptune Apex El Ended: 31 Aug, 2022 17:09:59 BST 275.00 Description eBay item number: 115500912874 Seller assumes all responsibility for this listing. In Fusion, click the down arrow next to your username at the upper right, then click Settings, To add a recipient, click the plus sign icon at the upper right. The output programming is only active when the output is set to AUTO, and the state of the output will be displayed above the tile: This brief introduction only touches on the main points of Apex programming. YzEzNWM4NWIxMjA0Zjg0NjRiMzdkOWI5YTJiMTljZmY2OTU3MmFiNGNjZDU3 Added a virtual output named Maintenance to disable the ATK while Im conducting maintenance. Neptune Systems has released its latest generation aquarium monitoring and controller systems. Over the past year Ive become much more comfortable and proficient in Apex programming, and I've become a frequent contributor on the Neptune Community Forums and Neptunes Apex Community Facebook group where I do my best to help answer questions posted by other confused users. Turns off powerheads, skimmer, and sets return pump to 1% for 5 minutes. NWQ0ZDcxNDIwYzcwYTBlMjAyYmZlZmY1ZjNhZjNkODg3Y2Q2NDBhNjUxYzFj This photo is from the Reef2Reef archives courtesy of, Product Launch: StinkSink Skimmer Odor Filter. Announcing the BRAND NEW Orphek Atlantik iCon! Hopefully this tutorial has been helpful. If FeedA 000 Then 1 Once you have your EmailAlm output programmed, but sure to leave its tile on the dashboard in the AUTO position. Here are some examples: Depending on what kind of lights you have, you can either configure them for dim cool white light to simulate the moon, or install dedicated moon lights in addition to your primary lights. Mjk0NzlkNTM1YTM5NjdjZGIzMTliYWJlYmUxMDFhNTJiOWRhNjE2MzNlZTBm Defer 000:10 Then ON, Set OFF One of the major limitations with alarm programming is that only the last line that turns the output On is the line of text youll receive in the notification. All of the information Ill provide is already publicly available, but hopefully the way Ill present it will explain things more clearly and in a single location. It can be used to utilize different battery back-up scenarios. This is because we want this Energy Bar outlet to respond to leaks by turning OFF. After adding a new entry, you will receive a verification code at that address or phone number. (the names of your optical switches may not match my example). It uses three separate timers: The timers define Delay before first run / Time to run / Delay until next run. This probe is only about 1/4 thick so it may be easily slipped under the edge of carpeting. Data acquisition, analysis and problem solving. If Float1 Open Then ON If you want to use If Time for a shorter duration, it would need to be combined with the Defer statement: This will cause it to wait until 10:01 to turn on, then turn off at 10:02. effectively giving you a 1 minute timer: Ill explain Defer in more detail in the next section. MARSH is a private reefing group. NmFhMDliOTIzMDcwOTI3YzI1OGM2MTU5OWNhMjdmNWNkODc4MDRiYzM4ZDA3 THE ULTIMATE MULTIPURPOSE FLUID-MONITORING DEVICE! Thats all for Feed Cycles. Rather than having it turn on and off every few minutes as dictated by the float switch for the slightest amount of evaporation, you can force it to run less frequently even though that means it needs to pump water a bit longer. I just tried setting Defer to 000:00and got this error: This tutorial will cover several aspects of power monitoring in an Apex environment: *Note: These topics do not apply to older Apex units or older Energy Bars. Four of the new tiles correspond to the 4 FMM ports, and will have a name in the format of SWX_#_*, where # is the Apex AquaBus address of the FMM and * is the number of the FMM port (1-4). NDIwMTZlODAzNmMzMGMzYjYzN2FiNzVmOTE3ZjdmYmRiZDU5ZDFmZWMyMzNk Be sure to configure your alarms. If Output Maintenance = ON Then OFF First, we will program our email alarm output. Earn 18,585 Reward Points, Earn 599 Reward Points $100.00 + $10.00 shipping . Lowered the When command timer from five (5) minutes down to three (3) minutes. Neptune Apex Controller Base Unit - New Gen. $519.90 Out of stock Neptune Neptune Apex Display Module - Next gen Grey (ADM) $148.40 Only 2 left! They are going to publish each topic as articles spread over several weeks. The Defer is just a countdown timer that once it expires, the output can then change state. Remember the When command is a failsafe that moves the output tile slider to the manual OFF position, so it will no longer run the program until you move it back to AUTO: Once I finish typing up this tutorial, Ill go refill my 2-part containers and then set the Alert_2Part virtual output back to AUTO. I really appreciate your work putting this together.

Franklin T9 Mobile Hotspot Not Working, Cristal D'arques France Genuine Lead Crystal Glasses, Cristal D'arques France Genuine Lead Crystal Glasses, Articles N